EntryPass N5150

EntryPass N5150 is an active network access-control panel reference with 5,000 published card-holder capacity, 10,000 event-memory entries, up to 4 configurable inputs and 2 dry-contact outputs. Review the reader layout, software and selected package before choosing quantity for a supply-only enquiry.

EntryPass · Full reference: EntryPass N5150

Choose quantity

Manufacturer reference

Manufacturer details describe the cited version. Confirm the exact unit and intended system.

Controller capacity and network

Device class
Active Network Control Panel
Processor
32-bit Freescale ColdFire processor at 60 MHz, as described in the model datasheet.
Operating temperature
0 °C to 40 °C. Confirm enclosure, site conditions and installation requirements.
Card-holder capacity
5,000 card holders as a published reference; confirm the installed firmware and system configuration.
Event memory
10,000 maximum events in the published table. Retention and system operation require confirmation.
Configurable inputs
Up to 4 digital/supervised inputs; confirm the selected functions and wiring.
Relay outputs
Up to 2 dry-contact relay outputs. Counts do not establish lock power, current or switching ratings.
Network port
10/100 Mbps RJ-45 Ethernet, self-negotiating as listed. No PoE supply capability is established.
Status indicators
Power, communication, LAN, event and error indicators are listed.

Monitoring and system functions

AC-fail monitoring
AC-fail monitoring is listed; confirm the connected power supply and monitoring circuit.
Battery monitoring
Firmware-controlled threshold monitoring can shut down the panel. Confirm battery, charger and threshold configuration.
Reader short-circuit protection
The protection scope is stated as the readers. This is not a complete system protection or lock-power rating.
Clock-battery scope
The on-board battery is described for the real-time clock only, not backup operation of the panel, locks or readers.
Published dimensions
158 × 90 mm (W × H), as listed in the datasheet. Confirm enclosure dimensions, depth, terminals and cable clearance separately.
Web configuration
A built-in web server is listed. Confirm supported configuration functions, current firmware and secure network access.
Active communication
ActiveTransmit and ActiveDownload are listed. Confirm server integration; no network latency or delivery guarantee is implied.
Door interlocking
On-board and cross-board interlocking are listed. The selected layout and safe egress must be checked by qualified personnel.
Car-park mode
Car-park mode is listed; it is not a complete barrier, vehicle-detection or payment system.
Reader-location configuration
Dynamic reader-location configuration is listed. Confirm actual supported readers and port assignment.
Operation profiles
Dynamic operation profiles are listed; choose and verify the application configuration.
Anti-passback
Peer-to-peer global anti-passback is listed. Confirm reader direction, system topology and configured rules.
Encryption selection
AES is listed. Verify supported firmware, key management and configuration; this is not a security certification or a claim that all interfaces are encrypted.

Reader, package and selection references

Ordering and package selection
The sheet distinguishes EP.N5150.PCB and EP.N5150.PSU ordering options. PCB-only and power-supply packages are separate; the catalogue label does not confirm which is supplied.
Wiegand reader interface
Wiegand is listed for reader communication. Confirm credential formats, actual reader count and supplied hardware.
OSDP reader interface
OSDP is listed for reader communication. Protocol version, secure-channel support and mixed-reader configurations require confirmation.
Access-level sets
255 access-level sets are listed. Confirm the actual software configuration.

Selection notes

  • This reference is limited to EntryPass N5150 in its own manufacturer datasheet. Confirm the supplied revision, reader arrangement, firmware, software and ordered package. Published capacities are references, not an ISD compatibility, safety or supply approval.
  • Readers, locks, enclosure, power supplies, batteries, software licences and installation are separate selections. Diagrams and photos do not confirm package contents or all illustrated readers operating simultaneously.
  • Wiegand, OSDP, AES and interlocking are not blanket third-party compatibility, secure-channel, certification or safe-egress approvals. A qualified person must verify the actual firmware and complete system.
  • Unresolved reader-count/layout, surge-unit and electrical-budget details must be confirmed before a design is accepted. The RTC battery does not back up door operation.
  • ISD supplies products only. Confirm stock, price, lead time, actual ordered package and local warranty separately.

Official documents

Manufacturer source checked 2026-10-20. The supplied unit and local terms require confirmation.

Continue browsing