Hikvision DS-PDBG8-EG2-WB is a wireless acoustic glass-break detector reference. The guide lists an 8 m acoustic radius, 120° coverage and two external inputs; the 433 MHz radio has a separate free-space range. Confirm glazing, curtains, room noise, panel compatibility and the exact supplied WB device before choosing a quantity.
Hikvision · Full reference: DS-PDBG8-EG2-WB
Choose quantityManufacturer reference
Manufacturer details describe the cited version. Confirm the exact unit and intended system.
Glass-break detection and indications
- Device class
- Wireless Glass Break Detector
- Detection principle
- An acoustic sensor and microphone are used for glass-break detection. This is not a PIR or vibration-contact detector.
- Acoustic detection reference
- 8 m radius with a 120° detection angle is listed. Glass, curtains, room acoustics and placement must be assessed; this is not a radio-range value.
- Sensitivity settings
- 2 m, 4 m, 6 m and 8 m settings are listed. Select and test for the actual protected glazing.
- Glass thickness reference
- 2.4–6.4 mm glass thickness is listed. Compatibility with a particular pane construction must be confirmed.
- Glass pane size reference
- The listed pane-size range is 0.3 × 0.3 m to 3 × 3 m. It does not confirm detection for every pane or glazing type.
- Digital signal processing
- Digital processing is listed. It is not a promise that all noise or false alarms will be rejected.
- Tamper monitoring
- Front and rear tamper protection is listed.
- Status indications
- Ambient-temperature and signal-strength indications are listed; the alarm LED is blue.
Inputs and radio communication
- External inputs
- Two external inputs are listed in the QSG. Confirm the intended circuit and wiring rather than treating these as extra radio detectors.
- Alarm input modes
- Normally closed, normally open and impulse-count modes are listed. Confirm the contact configuration and application.
- Wireless communication
- Tri-X two-way RF wireless communication is listed. It does not establish a Wi-Fi or wired network connection.
- Communication carrier
- 433 MHz is listed for this WB reference. No WE-band or local radio approval is inferred.
- Radio distance reference
- 1 km in free space is the stated radio range. This is not guaranteed indoor coverage or the acoustic detection radius.
- Frequency hopping
- Frequency hopping is listed. It is not a guarantee against all interference or jamming.
- Enrolment references
- Power-up, remote ID and QR-code enrolment methods are listed. Confirm the supported panel, app and regional service availability.
Battery, environment and selection
- Battery reference
- Two CR123A cells are listed. Manufacturer-described inclusion does not confirm the actual ISD package; do not derive a 6 V device rail from the cell count.
- Nominal power reference
- The source states 3 V DC. This is distinct from the battery count, capacity and low-voltage warning threshold.
- Battery capacity reference
- The QSG lists a maximum 1,600 mAh battery figure. It is not a measured operating life or confirmed supplied battery capacity.
- Low-voltage threshold
- 2.45 V is the listed low-voltage value. No remaining service interval is guaranteed.
- Maximum current reference
- 22 mA maximum current is listed. Confirm the applicable operating state and power source.
- Quiescent current reference
- 16 µA quiescent current is listed. This is microamperes, not 16 mA.
- Operating temperature
- −10 to 55 °C is listed for operation. Assess the actual enclosure and installation environment.
- Storage temperature
- −20 to 60 °C is the storage range, not the operating-temperature range.
- Operating humidity
- 10–90% relative humidity is listed. No non-condensing or outdoor ingress rating is added from this row.
- Weight reference
- 83 g is listed. Battery and packaging conditions are not stated in this weight row; it is not a shipping-weight promise.
- Location and mounting
- Indoor wall or ceiling mounting is listed. Keep the microphone opening and protected sound path unobstructed.
- Placement and testing
- The guide calls for signal and glass-break tests and warns about curtains, noise, humidity and vibration. Sponge-tape mounting is marked EN non-compliant; local compliance must be assessed separately.
Selection notes
- Manufacturer reference for DS-PDBG8-EG2-WB only. Confirm the supplied hardware, firmware, region, panel and installation conditions; WB, WE, (B) and wired versions are not interchangeable.
- ISD supplies products only. Manufacturer examples do not confirm ISD stock, price, ETA, actual supplied contents, local warranty, authorisation or approval. Qualified personnel must confirm the intended system and site.
- Follow the official battery, safety and installation instructions; keep new and used batteries away from children. No installation, monitoring service or actual device enrolment is included.
Official documents
Manufacturer source checked 2026-10-20. The supplied unit and local terms require confirmation.
IS DistributionsEnquire