DS-PM1-I16O2-WB

The DS-PM1-I16O2-WB is a multi-IO transmitter reference with 16 physical zone inputs, two relay outputs and a 433 MHz two-way radio. The guide separately identifies the battery connection and two 12 V output channels. Confirm detector wiring, power budget, relay loads and the exact WB system before an enquiry.

Hikvision · Full reference: DS-PM1-I16O2-WB

Choose quantity

Manufacturer reference

Manufacturer details describe the cited version. Confirm the exact unit and intended system.

Inputs, outputs and wiring modes

Device class
Multi IO Transmitter
Physical zone inputs
16 physical zone inputs are listed. Dual-zone wiring options do not establish 32 independent physical inputs.
EOL resistor choices
1, 2.2, 4.7 and 8.2 kΩ are listed EOL choices. Match the detector and programmed wiring mode; do not assume resistors are supplied.
Zone wiring modes
The diagrams show EOL for NC/NO, DEOL for NC/NO, dual-zone series, normally closed and normally open configurations. A qualified installer must verify the intended circuit.
Relay outputs
Two relay outputs are listed. The PGM/C diagram shows dry-contact wiring; no voltage/current contact-load rating is established.
Tamper switches
Two tamper switches, front and rear, are listed.

Radio and indications

Radio communication
Two-way 433 MHz radio with 2GFSK modulation is listed for this WB model.
RF distance reference
800 m in open area is the cited reference, not a site coverage guarantee.
LED indications
The specification lists alarm/tamper(red), fault(amber) and signal-strength(green/red) indications; appearance also identifies power and enrolment states.

Power and operating limits

Mains supply reference
100–240 V AC is listed. Mains connection and isolation require a qualified person and the official safety instructions.
Battery connection
One 12 V input is labelled for a battery connection. Battery chemistry, capacity, charger compatibility and runtime require confirmation.
12 V auxiliary-output reference
Two 12 V output channels are listed with a shared table statement of 1 A total consumption. Do not assign 1 A to each channel or use this as a relay-contact rating.
Weight reference
975 g without battery is listed. It is not the weight of a battery-equipped or packaged assembly.
Operating conditions
-10 to 40 °C and 10–90% humidity are listed. A weatherproof or non-condensing rating is not inferred from these rows.
Altitude limit reference
The guide states a maximum use altitude of 5,000 m. This is not a blanket environmental or local compliance approval.

Selection notes

  • This reference applies only to DS-PM1-I16O2-WB in the cited manufacturer document. Confirm the actual hardware, firmware, region, panel, power budget and supplied configuration; WB, WE, kit and other suffixes are not interchangeable.
  • Manufacturer capacity and component lists do not confirm ISD supplied contents, stock, price, ETA, local warranty, authorisation or Malaysian regulatory suitability. ISD supplies products only.
  • Qualified personnel must confirm the exact system, radio version, detector circuits, battery/power budget and relay loads. Use official instructions; no installation or monitoring service is included.

Official documents

Manufacturer source checked 2026-10-20. The supplied unit and local terms require confirmation.