DS-K1T343EX

A square-format face and EM-card access-terminal reference with an expressly indoor application scope. Confirm the credential format, access-system pairing and site conditions before choosing quantities.

Hikvision · Full reference: DS-K1T343EX

Choose quantity

Manufacturer reference

Manufacturer details describe the cited version. Confirm the exact unit and intended system.

Credentials & capacity

Terminal format
Face-recognition access terminal reference.
Authentication methods
Face and EM-card methods listed; confirm the configured policy.
Face capacity
Up to 1,500 face records in the manufacturer reference.
Card capacity
Up to 3,000 card records in the manufacturer reference.
Card reference
EM card; verify the actual credential.
Card frequency
125 kHz in the EM-card table.
Face-distance reference
0.3-1.5 m manufacturer reference; verify lighting, mounting and user position.
Face-time reference
Less than 0.2 s stated by the manufacturer; not an installed-site performance guarantee.
Event capacity
Up to 150,000 events in the manufacturer reference.
Card-distance reference
0-3 cm for normal cards and 0-2 cm for differently shaped cards in the source; verify the actual credential and mounting.

Display & audio

Display
4.3-inch capacitive LCD touch screen.
Camera reference
Two lenses with a 2 MP camera reference; recording mode and frame rate require separate checking.
Audio processing
Noise suppression and echo cancellation listed.
Two-way audio
Two-way audio with compatible client software and listed station types; verify firmware, network and pairing.
Display resolution
480 × 272 pixels; the screen resolution is separate from the camera resolution.
Camera field of view
75.5° horizontal, 41.5° vertical and 87° diagonal in the cited table.
Lens reference
4 mm focal length, F2.0 aperture.
Dynamic-range reference
WDR support listed; assess lighting and configuration.
Audio encoding
G.711U at 64 kbit/s in the audio table; verify the configured mode.

Connections & functions

Network interface
One RJ-45 port with 10/100 Mbit/s adaptive Ethernet.
RS-485 interface
One half-duplex Hikvision RS-485 interface; verify the paired device and protocol.
Wiegand interface
One interface with Hikvision 26-bit and 34-bit formats listed; verify direction, format and pairing.
Lock-control interface
One interface listed; relay-contact rating and lock supply require separate checking.
Exit-button input
One input listed.
Door-contact input
One input listed.
Tamper interface
One TAMPER interface listed.
USB interface
One USB interface listed; confirm function and firmware.
Protocol reference
SDK, SIP, RTSP, ISAPI and ISUP 5.0 listed; verify integration, versions and the required mode.
Web configuration
Web-client configuration listed; supported network and appropriate access are required.
Anti-spoofing reference
Face anti-spoofing listed; not an assurance against every attack or condition.
Platform reference
Hik-ProConnect and HikCentral Professional listed; confirm software, firmware, licences and service requirements.
Attendance reference
Attendance-only function listed; confirm configuration and intended use.

Power & mounting

DC-input reference
12 V DC, 1 A terminal input; confirm the supplied adapter and separate lock-power design.
Operating temperature
-10 to 40 °C in the exact-model table; assess actual site conditions.
Operating humidity
0-90%, non-condensing.
Listed dimensions
118.4 × 118.4 × 21.8 mm in manufacturer-listed order; verify projections and installed clearance separately.
Mounting reference
Wall or base mounting listed; verify actual arrangement and clearance.
Mounting accessory
Optional DS-KAB6-W1 bracket reference; confirm exact part and supply.
Application reference
Indoor application expressly listed; assess the actual site and operating-temperature scope.
Net-weight reference
0.23 kg net in the cited table; actual shipment weight is separate.
Gross-weight reference
0.71 kg gross in the cited table; confirm the actual supplied package.

Selection notes

  • Confirm the complete model and the cited hardware/firmware for the intended system.
  • Capacities, reading distances and performance references are manufacturer statements, not installed-site guarantees. Check credentials, lighting, mounting and configuration.
  • Interface counts are not relay contact-load ratings or universal controller/reader compatibility.
  • Remote functions require supported software/firmware, network, licences where applicable and appropriate access permissions.
  • ISD confirms the supplied unit, accessories, price, stock, lead time and local warranty separately.
  • Optional DS-KAB6-W1 is not automatically included. Source body dimensions are not an installed-clearance guarantee; verify all terminal and mounting projections.
  • Ethernet and DC supply do not establish IEEE PoE support. Confirm the intended power and door-control design.

Official documents

Manufacturer source checked 2026-10-15. The supplied unit and local terms require confirmation.

Continue browsing